Abstract: | A new kind of hydrogen-ma ser time and frequency Standard was installed this September at sheshan 25-meter radio telescope in Shanghai, for very long baseline interferometry (VLBI) experiments. This standard is a readily transportable, rugged and completely integrated frequency standard. The entire system is engineered as a unit, and all electronics were mechanically and electrically integrated with the physical portion into the overall design. This paper describes its design feature and structure as well as the measured results of its performance. Its applications and data in VLBI experiment are also included. |
Published in: |
Proceedings of the 21th Annual Precise Time and Time Interval Systems and Applications Meeting November 28 - 30, 1989 Sheraton Hotel Redondo Beach, California |
Pages: | 191 - 198 |
Cite this article: | Z.C.Zhai,, H.X.Huang,, C.F.Lin,, G.X.Jiang,, W.H.Luo,, J.F.Lu,, "A NEW HYDROGEN-MASER TIME AND FREQUENCY STANDARD AT SHESHAN VLBI STATION OF SHANGHAI OBSERVATORY," Proceedings of the 21th Annual Precise Time and Time Interval Systems and Applications Meeting, Redondo Beach, California, November 1989, pp. 191-198. https://doi.org/10.33012/1989.14518 |
Full Paper: |
ION Members/Non-Members: 1 Download Credit