Theoretical Studying About the Measurement of the C-Field Intensity in the Optical Pumped Cesium Frequency Standard

Junhai Zhang, Fengzhi Wang, Donghai Yang

Abstract: In the paper the measurement of the C-field intensity is analyzed theoretically in optical pumped Cesium frequency standard. The transition probability from the F=3 mF=0 level state to the F=4 mF=0 level state has been discussed as the function of the frequency and power of the signal injected to the low frequency coils. The result shows out the fluorescence intensity in the probing region increases to 1.37 time of the normal condition without the low frequency signal at the Ramsey cavity.
Published in: Proceedings of the 37th Annual Precise Time and Time Interval Systems and Applications Meeting
August 29 - 31, 2005
Vancouver, Canada
Pages: 598 - 601
Cite this article: Zhang, Junhai, Wang, Fengzhi, Yang, Donghai, "Theoretical Studying About the Measurement of the C-Field Intensity in the Optical Pumped Cesium Frequency Standard," Proceedings of the 37th Annual Precise Time and Time Interval Systems and Applications Meeting, Vancouver, Canada, August 2005, pp. 598-601.