Abstract: | At BEV, in cooperation with PTB and Joanneum Research/TU Graz and the support of BIPM, we have done a calibration of the BEV reference GPS time receiver by using Two-way Satellite Time and Frequency Transfer (TWSTFT). Due to antenna changes, a new calibration of the BEV receiver was necessary. This receiver is the first GPS receiver with calibration through TWSTFT and used for UTC computation. This new calibration technique improves the value of the UTC-UTC (BEV) uncertainty in the Circular T from 5.3 ns down to 3.6 ns. |
Published in: |
Proceedings of the 40th Annual Precise Time and Time Interval Systems and Applications Meeting December 1 - 4, 2008 Hyatt Regency Reston Town Center Reston, Virginia |
Pages: | 543 - 548 |
Cite this article: | Niessner, A., Mache, W., Blanzano, B., Koudelka, O., Becker, J., Piester, D., Jiang, Z., Arias, F., "Calibration of the Bev GPS Receiver By Using TWSTFT," Proceedings of the 40th Annual Precise Time and Time Interval Systems and Applications Meeting, Reston, Virginia, December 2008, pp. 543-548. |