Previous Abstract Return to Session A5 Next Abstract

Session A5: Applications of Time Transfer and Dissemination

Validating the Timing Performance of Iridium PNT Receiver's STL - Time Service that Utilizes only Signals from Low Earth Orbit Satellites
Pete Johnson, Iridium
Location: Ballroom C
Date/Time: Tuesday, Jun. 2, 9:35 a.m.

We present the timing accuracy of Iridium® PNT receivers by validating the timing service (STL - Time) against the timing reference from a traditional Global Navigation Satellite System (GNSS) timing receiver and the timing reference at the National Institute of Standards and Technology (NIST) in Boulder Colorado for a durations up to 40 days. Iridium PNT is a mature LEO based timing and location service that is fully deployed and available worldwide today. This paper focuses on the Iridium PNT receivers timing solution and measuring its stability and accuracy relative to UTC from a GNSS timing receiver and UTC(NIST). The data show that an Iridium PNT receiver with a miniature atomic clock (MAC) oscillator provides a stable timing solution with an average time offset to UTC close to zero, a maximum offset to UTC less than 40 ns and Maximum Time Interval Error (MTIE) less than 80 nanoseconds over a period of 40 days. The time deviation (TDEV) of the Iridium PNT receiver with a MAC oscillator is less than 6 ns after one day of averaging, and the stability (ADEV) is close to 1 × 10-13 at one day continuing to average down to below 2 × 10-14 at 7 days. These results show that an Iridium PNT receiver maintains a highly accurate and stable timing solution in scenarios where GNSS signals are compromised or cannot be received at the user's location.



Previous Abstract Return to Session A5 Next Abstract